NIDV-16
Non-Isolated Differential Voltage Module
16-Channel Non-Isolated Differential Voltage Module
The NIDV-16 input module provides 16 nonisolated differential voltage inputs and 12V DC for powering external transducers. Connections are made via two 25-pin D-sub connectors.
Non-Isolated Differential Voltage Module Key Benefits
- 16 voltage inputs (30 Vrms or 50 V DC max)
- Simultaneous sampling at up to 200kS/s/ch
- 16-bit resolution
- 9 input ranges to maximize measurement resolution
- Built-in counter and timer functions including quadrature event counter
- Screw terminal or BNC connections with adaptor
Compatibility
TMX®, TMX-18, and TMX-R data acquisition systems
Typical applications
- Process monitoring and control
- Troubleshooting and repair
- Product verification and validation
+-Specifications
Analog Inputs
- Channels Per Module: 16
- Connector: Two 25-pin D-sub male connectors
- Input: Differential, DC coupled
- Bandwidth: 40 kHz (-3dB)
- Isolation: No
- Sample Rate: 200 kS/s/ch (100 kS/s/ch when using TMX-E or TMX-R)
- A/D: 16 bit SAR (one per channel)
- Anti-Aliasing Filter: 4 pole Bessel
- Cold Start Drift: < 0.5% att (60 min.)
- Off Ground Measurements: Yes
- Zero Suppression: Yes, digital
- Attenuator Ranges: 200, 400 and 800 mV; 2, 4, 5, 10, 25 and 50 V
- Measurement Ranges: +/- 200 mV (80 to 160 mVFS or 400 mVFS w/ zero offset) +/- 400 mV (400 mVFS or 800 mVFS w/ zero offset) +/- 800 mV (800 mVFS or 1.6 VFS w/ zero offset) +/- 2 V (1.6 VFS or 4 VFS w/ zero offset) +/- 4 V (4 VFS or 8 VFS w/ zero offset) +/- 5 V (5 VFS or 10 VFS w/ zero offset) +/- 10 V (10 VFS or 20 VFS w/ zero offset) +/- 25 V (20 VFS or 50 VFS w/ zero offset) +/- 50 V (50 VFS or 100 VFS w/ zero offset)
- Max Rated Input: 30 Vrms or 50 VDC
- Max Common Mode Voltage: +/- 60V
- DC Accuracy (25°C): +/- 0.07% of attenuator (800 mV, 2, 4, 5, 10, 25 and 50 V attenuators) +/- 0.1% of attenuator (400 mV attenuator) +/- 0.15% of attenuator (200 mV attenuator)
- Overshoot: < 1%
- Intrinsic Noise (pk-pk): < 0.1% of attenuator + 4 mV
- CMR at 60 Hz: Better than -60 dB
- Min Input Impedance: > 500 KΩ (250 KΩ balanced to signal common)
- Excitation: No
- Auxiliary Power Output: Yes. 12V @ 200 mA (total of the two connectors)
Counter Timer
- Frequency Counter Capability: Yes, Software selectable on channels 1 and 2
- Counter Modes: Gated time frequency counter, cycle based frequency counter, pulse counter, quadrature counter, pulse width detector, period width and duty cycle detector
- Frequency ctr range (menu): 2 – 50 kHz
- Frequency ctr range (spec’d): 2 – 40 kHz (48 Hz – 100 kHz for cycle based frequency counter)
- Frequency ctr accuracy: + 0.05% of Measurement + .002 Hz
- Min counter input amplitude: 25% of span for freq and pulse counters, 90% of span for all other modes
- Pulse counter range: 64000000 maximum. (16 bit display resolution)
- Pulse width accuracy: 1.5 μs +.00167% of span
- Pulse width range: 40 μs – 40000 μs
- Edge separation accuracy: .002% of measurement + .00167% of span + 0.7 μs
- Edge separation range: 100 μs – 5000000 μs
- Period width accuracy: .02% of measurement + .00167% of span with a maximum of 1.0 μs
- Period width range: 5 μs – 90000 μs (11 Hz – 50 kHz)
- Duty cycle accuracy: .5% (Inputs in the 15 Hz – 10 kHz range with 20% – 80% duty cycles)
- Counter Timebase: 50 MHz
Optional accessories
| ADP-20 D-Shell to BNC Adaptor labeled Channel 1-8 (extra) 1 included at no charge with each NIDV-16 , P/N: 32031000 |
| ADP-916 D-Shell to BNC Adaptor labeled Channel 9-16 (extra) 1 included at no charge with each NIDV-16 , P/N: 32031009 |
| HC-TMX Hard Transport Case for TMX , P/N: 41047010 |
| HC-TMXE Hard Transport Case for TMX and Expansion Chassis, P/N: 41047020 |
| SC-TMX Soft Carry Case for TMX, P/N: 41047000 |
Available services
- 1-Year extended warranty
- Factory calibration service