Isolated Voltage Input Module
8-Channel Isolated High Voltage Module
The ISEV-8 in an 8-channel isolated voltage input featuring a high dynamic range, IEPE excitation for accelerometers and microphones, and BNC connectors for simplified wiring.
Isolated Voltage Input Module Key Benefits
- 8 isolated voltage inputs (150 Vrms or DC)
- Simultaneous sampling at 100 kS/s/ch or 12.5 kS/s/ch
- 150 VRMS, DC Cat II isolation
- 24-bit resolution
- Convenient BNC connectors
- IEPE support
- 7 measurement ranges
- Built-in hardware-based counter
and timer functions
Compatibility
Daxus® DXS-100 and SmartCorder® DDX-100 data acquisition systems
Typical applications
- Research and Development
- Product verification and validation
- Applications requiring high accuracy AC or DC measurements
+-Specifications
ANALOG INPUTS
- Channels Per Module: 8
- Connector: Isolated BNC
- Input: SE Voltage DC coupled, SE Voltage AC coupled, IEPE, Continuity
- Bandwidth: 13 KHz (100 KHz output data rate) | 3 KHz (12.5 KHz output data rate)
- Sample Rate: 100 KHz, 12.5 KHz (Selectable per module)
- Rated Isolation: 150 VRMS or DC, Cat II (channel to chassis and other channels)
- A/D: 24 bit (one per channel – scaled to 16-bit for Daxus/DDX100)
- Anti-Aliasing Filter: Hybrid – cutoff based on output data rate
- Cold Start Drift: < 0.04% of attenuator (60 min.)
- AC Coupled 3dB Point: < 0.54 Hz
- Off Ground Measurements: Yes
- Zero Suppression: Yes, digital
- Attenuator Ranges: 1, 10, 100, 200 and 400 Volt
- Measurement Ranges: +/- 200 V (200 VFS or 400 VFS w/ zero offset)
+/- 100 V (100 VFS or 200 VFS w/ zero offset)
+/- 50 V (50 VFS or 100 VFS w/ zero offset)
+/- 10 V (10 VFS or 20 VFS w/ zero offset)
+/- 5 V (5 VFS or 10 VFS w/ zero offset)
+/- 2 V (2 VFS or 4 VFS w/ zero offset)
+/- 1 V (1 VFS or 2 VFS w/ zero offset)
- Max Rated Input: 150 Vrms or DC, Cat II
- Max Transient Input (5s): +/- 300 V (Voltage input – no damage)
- DC Accuracy (25°C): +/- 0.03% of attenuator
- Overshoot: < 0.6%
- Intrinsic Noise (pk-pk): < 0.36% of attenuator (1 V att)
< 0.182% of attenuator (2 V atts)
< 0.072% of attenuator (5 V att)
< 0.039% of attenuator (10 V atts)
< 0.015% of attenuator (50 V, 100V & 200 V atts)
- IMR at 60 Hz: Better than -95 dB
- Min Input Impedance: > 1MΩ
COUNTER TIMER
- Frequency Counter Capability: Yes, 1 for each of the 16 output (processed) channels. Software selectable
- Counter Modes: Gated time frequency counter, cycle based frequency counter, pulse event counter, gated
pulse event counter, pulse width detector, period width detector, duty cycle detector, edge
separation (phase) detector.
- Frequency Ctr Range (menu): Up to 80 KHz (Up to 40 KHz for cycle based)
- Frequency Ctr Range (spec’d): 2 Hz – 12 KHz
- Frequency Ctr Accuracy: + 0.003% of Measurement + .00167% of span + .001 Hz (cycle based)
+ 0.01% of Measurement + .00167% of span + .001 Hz (time based, min avg time)
- Min Counter Input Amplitude: 25% of att for freq and pulse counters, 90% of att for all other modes
- Pulse Counter Range: 4000000000 maximum. (16 bit display resolution)
- Pulse Width Accuracy: .004% of measurement + .00167% of span + 0.2 μs
- Pulse Width Range: 400 μs – 2500000 μs
- Edge Separation Accuracy: .002% of measurement + .00167% of span + 0.2 μs
- Edge Separation Range: 400 μs – 3000000 μs
- Period Width Accuracy: .004% of measurement + .00167% of span + 0.1 μs
- Period Width Range: 400 μs – 4000000 μs (0.2 Hz – 10 KHz)
- Duty Cycle Accuracy: .5% (Inputs in the 0.3 Hz – 500 Hz range with 5% – 95% duty cycles)
- Counter Timebase: 50 MHz